Today’s sophisticated process-control systems require a deep understanding of the specifications of each element in the control package. Since each component will help ensure that your automated valve performs to standards, understanding the uses and limitations of every part of your actuator is critical to the valve’s overall success.
Xingyu contains other products and information you need, so please check it out.
Although valve actuators are essential to any valve-automation package, many other elements play important roles in valve system communication and process/flow-control requirements, including:
An automated valve system should include the following specifications:
But before you can start to think about the rest of your specifications, you need to choose the type of valve actuator that works best with your setup. The choice between a pneumatic and an electric actuator will impact the rest of your valve-specification process.
Note: Consult the valve manufacturer for specific Safety Factor recommendations.
Both pneumatic and electric actuators are useful across a broad range of valve applications. Each type of actuator has its advantages and disadvantages, and choosing one depends primarily on your application’s specific requirements.
The main points to consider when comparing the two are:
To learn more about these specifics and other variables, download our free eBook, “How to Select an Actuator.”
Actuator torque and sizing depends on your valve’s applications. If you intend your valve for a process that handles clean liquids at moderate pressures and temperatures, the manufacturer’s published operating torque usually suits your actuator’s size.
But if your valve operates under other conditions (e.g., unique liquids, extreme temperatures, or high/low pressures) you may need to increase the torque to adequately operate your valve.
If this is the case, you’ll need a sizing safety factor, which you can apply based on the following guidelines:
Electric actuators are geared motors with a variety of electrical components (i.e., limit switches, heaters, and circuit boards) built to meet the exact automation requirements of a process-control system. Since these actuators run on electrical components, they’re housed in enclosures designed for specific area classifications based on NEMA ratings.
One of the critical differences between pneumatic and electric actuators is the power source that drives their motions. With electric actuators, electricity drives the actuator to produce movement.
Let’s look at some of the considerations for electric actuators.
Specifications ChecklistHere are some of the basic specifications you should check when choosing an electric actuator:
Electric actuator limit switches provide the necessary number of electrical contacts in the open, closed, or intermediate positions. Most standard electric actuators have two SPDT limit switches—one for the open position, and one for the closed position—to control rotary travel as desired. You can always specify additional contacts that you may need in either the open, closed, and intermediate positions.
A manual override is a safety and productivity mechanism that provides valve operations in the case of an electrical failure or for startup and setup procedures. The handwheel should not rotate during normal operations.
Actuators with an output of in-lbs torque or higher may require the use of torque switches. These components protect your automated valve and motor, and they’re necessary for the tight closure of torque-seated valves.
Since electric actuators use geared motors that have fixed speeds relative to the layout of the gear train, some manufacturers offer electronic speed controls that use a rotary output to increase speeds (usually 5–25 seconds for 90°). If you require a cycle time greater than the one specified, you should invest in an actuator with an electronic speed control to improve speed and cycle times.
There are multiple separate control options to consider with electrical actuators:
Electric actuators use positioners to position the valve in response to a control signal. They rely on input maDC signals and optional position transmitters.
A position transmitter provides continuous feedback for the valve position. You can get these with a slide wire (potentiometer) and either a two- or four-wire 4–20 maDC output. Two-wire outputs have integral power supplies, but four-wire outputs require a power supply.
See Indelac Pneumatic Actuators: Double Acting & Spring Return
One of the most appealing aspects of electric actuators is their versatility across many different valve-automation requirements. This means that you can easily configure control cards, wirings, and switches to meet your granular needs.
A three-position control package can provide 0°, 90°, and 180° rotation for multiported three-position valves. These actuators come with mid-position stops from both or either extreme. If you elect to stop from either extreme, you can also choose between clockwise and counterclockwise motions.
If you are looking for more details, kindly visit Electro Pneumatic Valve.
These systems also incorporate integral local control stations that mount directly to actuator housing. These stations include local/remote switches plus open/close switches for local operation. Additional optional features include key locks and open/close lights.
Electric actuators come with many additional customization options and add-ons, including:
The other type of actuator — pneumatic actuators — use compressed air (or gas) to power their motions. You can also select from a few different variables when configuring your pneumatic actuator.
You will need to select your sizing data necessary for your pneumatic valve. Considerations for this process include:
Unlike electric actuators, pneumatic actuators are piloted by a solenoid valve. The manufacturer will size this valve flow rate to help provide adequate speed of operation.
There are five main types of pilot valves to choose from, and each comes with further modification potential:
These valves can be built from materials including aluminum, bronze, and stainless steel. In addition, coils can be modified to a number of specifications, such as:
Also, you can select from the following pilot valve options:
Finally, you will need to specify the actuator’s speed of operation in one or both cycle directions. Most pilot valves include NPT exhaust ports that may be fitted with a needle valve or with speed-control valves that function in either the open or closed direction.
Pneumatic actuator valves also rely on limit switches to indicate the closed, open, and intermediate positions of the valve. These are electrical components, so they need to be housed in NEMA-rated containment units to meet area classifications.
Here are some specifics that you can choose from when it comes to limit switches.
Positioners are used with piston actuators and some diaphragm actuators to convert a control signal to a valve position in modulating service. There are two basic styles of positioners: pneumatic and electro-pneumatic.
· Pneumatic positioners have input-control signals that measure inputs in pounds per square inch. They also have signal/position psigs for valve-open and valve-closed conformations. They can be built with linear, quick-opening, and other cam styles, and they include visual indicators for ease of use.
· Electro-pneumatic positioners measure input control signals in milliamperes. They also measure signal and position in milliamperes for valve-open and valve-closed conformations. Like pneumatic positioners, they can be designed with linear, quick-opening, or other cam styles depending on their application. However, they offer more customization options than pneumatic positioners.
Most off-the-shelf quarter-turn valves have equal percentage flow characteristics. This is generally acceptable for most applications. If other characteristics are required, a replaceable characterized cam may be used.
Additionally, manufacturers can opt for rotary position transmitters. These devices provide continuous feedback of the valve position with a resistive or current output signal. They achieve this using a potentiometer, but these devices may not be accurate over long distances due to the inherent resistance of the wire. It’s important to specify the resistance range of these transmitters, but most of them default to 90° of rotation. They achieve current feedback through a resistance-to-current conversion circuit, which is generally preferred for transmission over long distances. They can achieve outputs of 4–20 mA over 90° of rotation, and they can be rated as NEMA 4, NEMA 7, or NEMA 4X depending on construction.
Choosing the correct electric pneumatic actuator can be difficult. We at Indelac offer expert actuator consulting and services for a diverse range of clients. If you don't know what specifications you need, we can help walk you through the selection journey.
If you’re looking to take advantage of an electric actuator for your automated valve processes, contact us today.
Selecting the appropriate valve for any application is imperative to ensure proper direction of flow, flow rate, exhaust function, and even basic valve functionality.
Valve function outlines the number of flow paths a valve has as well as the positions of a valve. The flow paths or ports are referred to as ways in the valve function. The number of positions is how many different positions that valve can be in.
Valve Porting pertains to the usability of the port and the direction of flow through the valve in different positions. There are two key points we will cover. First, the usage of the port—can we physically connect to the port? And second, the flow direction that the valve must accommodate for the application.
The actuation is what shifts the valve from one position to another and there are two popular types that need to be considered in selecting the proper valve for any application. The actuation can be any of the functions or porting discussed above and is another valve characteristic that is important to understand.
For help selecting the best valve for your application, call 877-245- or contact your local distributor.
By Mike Kettering • Technical Sales Specialist • Clippard
For more Fluid Control Solutionsinformation, please contact us. We will provide professional answers.
{Check now} If you are looking for {more details}, kindly visit our website. XYZKF-CTA(B)-E VACUUM GENERATOR HEPV HIGH PRESSURE ELECTRONIC REGULATOR {Read more} You can find {more information} on our web, so please take a look. You can find {more information} on our web, so please take a look. If you want to {learn more}, please visit our website. {Read more} You can find {more information} on our web, so please take a look. XY5120A Directional Control Valve XINGYU Drain Valve Automation Components Fluid Control Solutions 2L-300 Solenoid Valve Automation Components