Battery-operated clocks with frequency instabilities in the 10-11 range for time intervals of up to a day, and in a package not larger than 1 cm3, could find widespread use in portable electronic devices. Certain military [2,3] and civilian [4] applications, such as jam-resistant global positioning systems and synchronization of mobile communication and navigation networks, demand timing precision that cannot be reached with low-power quartz crystal technology over time intervals of more than a few minutes. Atomic clocks can provide these stabilities, but state-of-the-art atomic clocks are large (~100 cm3) and consume several watts of power, making them unusable for portable applications. Chip-scale atomic clocks (CSACs) could bridge this gap. Recently, the first CSAC physics package was demonstrated [1].
California Triangle supply professional and honest service.
The microfabricated frequency references being developed at the National Institute of Standards and Technology (NIST) are based on miniature cells containing an alkali atom vapor fabricated by use of etched Si wafers bonded to glass windows [5,6]. The miniature cells used in the devices described here were filled with 87Rb by reacting BaN6 and 87RbCl in a controlled environment. The reaction produces alkali atoms, Ba, Cl, and N2 in addition to the 87Rb. Before sealing the cell by anodic bonding [7], most of the nitrogen produced in the reaction was pumped off, and the vacuum chamber, including the interior of the cell, was backfilled with 24 kPa of neon and 11 kPa of argon. The interior volume of the cell was 1 mm3. The cell was integrated with heaters, an optics assembly, a vertical-cavity surface-emitting laser (VCSEL) light source, and a photodetector to form a functional physics package for an atomic clock of volume 12 mm3, consuming 195 mW of power at an ambient temperature of 22 °C ( Fig. 1 a). The power to run the electronics and the synthesizer are not part of the 195 mW of power dissipation at present. In a final design, it should be possible to reduce the total power required to operate the complete system to below 50 mW.
The atomic hyperfine resonance was excited by use of coherent population trapping spectroscopy (CPT) [8] on the D1 lines of 87Rb ( Fig. 1 (b)). The two phase-stable circularly polarized light fields were produced by modulating the current of the VCSEL at half the frequency of the ground-state hyperfine splitting, creating two first-order sidebands on the optical carrier separated by the full atomic hyperfine splitting of 6.8 GHz. The laser wavelength of 795 nm was then tuned so that these two sidebands were resonant with the transitions from the two ground states to the excited 5P1/2 state. A longitudinal magnetic field was applied to lift the degeneracy of the Zeeman sub-states. The modulation frequency was tuned such that the CPT resonance associated with the two first-order magnetically-insensitive components mF=0 was excited. The resonance was detected by measuring the transmitted optical power by use of phase-sensitive detection with a lock-in amplifier. A feedback loop stabilized the modulation frequency of 3.4 GHz onto the center of the CPT resonance.
The red dots in Fig. 2 show the Allan deviation versus averaging time for the clock described above. The cell was heated to 120 °C to increase the vapor pressure to the point where the optical absorption through the cell was 25 %. The measured short-term stability of 4×10-11/τ1/2 was consistent with an estimate based on the width and amplitude of the dark line resonance and the detection noise. Since the detection noise was within a factor of two of the shot-noise level, the properties of the dark line resonance had the largest and most direct impact on the stability of the clock. The fractional reduction in absorption of the laser light due to the CPT was 4.6 %. The improvement of the short-term stability over the first CSAC physics package developed by our group at NIST using the D2 line of cesium (blue squares in Fig. 2 ) was due mainly to the increase in resonance contrast, which is caused by the following differences: Firstly, 87Rb has eight ground-state Zeeman components, half the number of Cs, so when the atomic population is distributed equally among the levels ¼ of the atoms are found in the mF=0 states. Secondly, selection rules allow single-photon transitions out of the dark state to the excited P3/2 state, but not to the P1/2 state. The longer lifetime of the dark state using the D1 line [9,10] results in a larger resonance amplitude and thus a better short-term stability of the clock. Finally, the two Λ-systems formed by the 0-0 ground states and the mF=-1 states of the two excited state hyperfine components can have a “coherent dark state” simultaneously [9], which is not the case for Λ-systems formed by the corresponding levels connected with the D2 lines. Nevertheless, the normalized CPT resonance amplitude is still lower than the one measured in centimeter-sized cells containing 87Rb. This is due most likely to off-resonant excitation to the strongly homogeneously broadened P1/2 state by the carrier and second-order sidebands of the laser field.
The CPT linewidth was measured to be 9.3 kHz. Nearly one third of this width is a result of power broadening from the 125 µm diameter laser beam of power 3.5 µW. The remaining linewidth is dominated by spin-exchange collisions between the Rb atoms, while contributions due to collisions of the Rb atoms with the cell walls and the buffer gas atoms play a minor role.
Are you interested in learning more about chip scale atomic clock? Contact us today to secure an expert consultation!
From Fig. 2 it is also apparent that the rubidium CSAC physics package also had a much improved long-term stability as compared to its Cs predecessor. The clock frequency is plotted as a function of time in Fig. 3 . From the red line in Fig. 3 a linear drift of -5×10-9/day was measured. It appears likely that the chemical reaction that produced the Rb generated some nitrogen gas that was not completely pumped away before the cell was sealed. The barium residue that remained on the cell walls after the initial chemicals have reacted could then have recombined with the residual N2, decreasing the N2 pressure over time and causing a drift in the CPT frequency. Since barium does not react with noble gases, the Ne and Ar buffer gases also contained in the cell should not contribute to the slow frequency drift. Nevertheless, this clock demonstrated a substantial improvement over the long-term stability of the first cesium clock (blue line in Fig. 3 ), for which nitrogen was one of the primary buffer gases contained in the cell. To reduce the instability at long times to the 10-11 range, we must eliminate the slow reaction and improve our control over the cell temperature. Thermal isolation of the cell by vacuum packaging and an advanced package design, as well as a better temperature sensor, are important future improvements to be considered.
The temperature of 120 °C at which the cell had to be operated to achieve 25 % absorption is higher than expected from the vapor pressure and absorption cross-section. We believe that a reason for this can be found in the existence of a trapping state that exists for left-hand circularly polarized light in a longitudinal magnetic field on the D1 line: atoms can accumulate in the “stretched state” |5S1/2, F=2, mF=-2〈, since they cannot be excited by the light field from there. Note, that this state is not the coherent dark state used for the clock interrogation, but a single Zeeman state which cannot interact with the light fields. Furthermore, the circularly polarized light pumps atoms towards that state. Buffer gas collisions, on the other hand, depolarize the excited P1/2 state, counteracting the optical pumping towards the “stretched state”. But even for complete depolarization in the excited state, a substantial fraction of atoms would still get trapped in the “stretched state” for D1 excitation [11]. At a buffer gas pressure of 32 kPa we estimate a depolarizing collision to happen roughly every 4 ns for atoms in the excited P1/2 state, an order of magnitude less frequently than for atoms in the P3/2 excited state [12]. Since this rate is close to the excited state lifetime of 28 ns, additional optical pumping towards the “stretched state” may be significant. Some evidence of this can be found when comparing the CPT resonances that couple the magnetically sensitive states with the same magnetic quantum number. The amplitude of the (-1; -1) resonance is twice as high as the (+1;+1) resonance using the laser power at which the CSAC is operated. For very low light intensities however, we find a ratio of the amplitudes of roughly 1.3. This indicates that the population in the mF=-1 Zeeman-states is higher and optical pumping toward the “stretched state” takes place.
The “stretched state” is dark for the circularly polarized laser light and therefore these atoms contribute neither to the CPT resonance nor to the Doppler-broadened background absorption. But they do affect the performance of the clock because they can collide with the alkali atoms in the dark state, thereby broadening the CPT resonance. In fact, we estimate the broadening of the CPT resonance due to spin-exchange collisions to be the dominant broadening mechanism for the Rb D1 CSAC. Furthermore, since the alkali density has to be several times higher on the D1 line than on the D2 line to achieve the same absorption, the vapor cell has to be heated to a higher temperature and therefore a clock based on D1 excitation might in principle require more power to operate.