Pressure-activated check valves prevent contamination and flooding from water sources used in fire protection systems

A check valve is a device that permits the flow of semisolids, liquids, or gases in only one direction. Check valves, featured in systems ranging from residential plumbing to pharmaceutical production, often rely simply on changes in pressure to manage flows.

LEFLOW Product Page

In this article, we’ll focus on check valves for fire protection, discussing how they work, the types of check valves, and their benefits in fire sprinkler systems. Additionally, we’ll help you understand what components you should look for when selecting a check valve and discuss how to maintain them.

Already know what you need? Feel free to go straight to our check valve product page and selection of grooved riser check valve trim kits.

How does a check valve for fire protection work?

Each fire sprinkler system needs a dependable source of water for immediate use in a fire emergency. Most systems use some combination of gravity tanks, municipal water supplies, and sometimes fire department connections to provide water to sprinkler heads. But while multiple potential water sources provide an extra layer of reliability to fire protection systems, they can also be problematic: drinkable water might be contaminated by water from a fire hydrant, or dirty water from fire sprinkler pipes might flow through nearby streets and into nearby drains. In many other applications, it’s simply important that water only goes one way for performance reasons. These include protecting equipment such as pumps and filters from backflow damage, stopping drainage in a fire sprinkler system with elevation changes, providing pressure relief in liquid or pneumatic applications, and more.

Check valves for fire protection prevent the unwanted reverse flow of water, known as backflow, from occurring. Many check valves feature a hinged clapper with a spring, which keeps the valve closed until the water flowing from some water source opens it. These clappers only open in one direction: when these flows reverse (or very nearly stop), the spring presses the clapper against a rubber seat, forming a water-tight seal.

Think of the water on either side of the clapper as the supply side (between the water source and the check valve) and the system side (between the check valve and the rest of the system). When a fire sprinkler head discharges, water is released, decreasing the pressure on the system side. Shortly after, the higher pressures from water stored or pumped from the supply side push open the clapper, and water flows through the system.

How does a check valve for fire protection prevent contamination of potable water?

When multiple water supplies serve the same fire sprinkler system, each must have a check valve.

From the Edition of NFPA 13

16.9.4.1 Where there is more than one source of water supply, a check valve shall be installed in each connection.

Check valves decide which source actually provides the system with a supply of water at a given moment. When multiple water sources are used simultaneously, only the check valve connected to the highest-pressure water source remains open. Imagine you have a system with three water sources at the following pressure ratings, expressed in pounds per square inch (PSI):

Active Water Sources Check Valve Status 100 PSI Fire Department Connection (FDC)
75 PSI Gravity Tank
50 PSI City Water
FDC, Gravity Tank, & City Open Closed Closed Gravity Tank & City Water Closed Open Closed City Water Only Closed Closed Open

(Note: these pressure levels are provided only as illustrations and are not meant to be taken as typical for these water sources.)

When water is supplied from all three sources, only the check valve leading to the fire department connection remains open. Why?

Of these three sources, the FDC delivers the highest water pressure. This supply pressurizes the water on the system side. This increased system-side pressure is greater than the 75 or 50 PSI on the supply side of the check valves connected to the other water sources and, as a result, their clappers close.

To continue with this example, if only the city water and the gravity tank supply water, the check valve to the 75-PSI gravity tank will open, while the city water’s check valve stays closed. Only when all other sources are exhausted or closed does the municipal water supply open the check valve and flow into the system.

What are the types of check valves for fire protection and their benefits?

There are four main types of check valves for fire protection:

  • Alarm check valve
  • Swing check valve
  • Grooved check valve
  • Grooved shotgun riser check valve
  • Backflow preventers comprising multiple check valves

An alarm check valve consists of a spring, a valve clapper, and an alarm port. The alarm port can be used to direct water to a water motor alarm or an alarm pressure switch used to alert nearby personnel to the system’s activation or send a signal to a fire alarm control panel.

A swing check valve can act as an alarm check valve for a wet-pipe fire sprinkler system, but only when that valve can sound an alarm.

From the edition of NFPA 13

16.11.3 Waterflow Detection Devices.

16.11.3.1 Wet Pipe Systems.

The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed waterflow detection alarm device with the necessary attachments required to give an alarm.

Typically, these alarms are sounded by flow switches, which send a signal to local alarms and/or the fire alarm control panel when water flows through system piping.

Grooved check valves are a type of swing check valve for use in systems that have grooved-connecting pipe ends. Many grooved check valves can be used in a vertical or horizontal orientation, allowing them to be used in various configurations with a fire department connection, bypass connection, gravity pressure tank, or pump discharge connection.

A grooved shotgun riser check valve is similar to a grooved check valve but includes pressure gauges to monitor the supply and system pressure. The shotgun configuration, which uses an electric water flow switch and an alarm bell, is only permitted in situations where a water motor alarm is not required. Shotgun riser check valves offer a more compact and economical alternative to an alarm check valve.

Finally, there are backflow preventers that are explicitly designed to prevent the contamination of water supplies. They use check valves and extra fail-safes to make absolutely sure water flows one way and doesn’t contaminate potable water supplies. You can read more about them in our other blog: “Backflow Preventer vs. Check Valve: What’s the Difference?”

Do check valves require periodic maintenance?

Yes, check valves require periodic inspections and maintenance. For this reason, NFPA 13 warns against burying check valves or positioning them in areas where they will be inaccessible.

From the Edition of NFPA 25

13.4.2 Check Valves

13.4.2.1 Inspection. Valves shall be inspected internally every 5 years to verify that all of the valve’s components operate correctly.

13.4.2.2 Maintenance. Internal components shall be cleaned, repaired, or replaced as necessary in accordance with the manufacturer’s instructions.

Alarm check valves and system riser check valves require more frequent inspections. Regular inspections help to verify that the clapper functions properly, that the valve seat is in good condition, and that there aren’t any visible signs of corrosion or blockages.

From the edition of NFPA 25

13.4.1.1* Alarm valves and system riser check valves shall be externally inspected quarterly and shall verify the following:

The company is the world’s best double door check valve supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

(1) The gauges indicate normal supply water pressure is being maintained.
(2) The valves and trim are free of physical damage.
(3) All valves are in the appropriate open or closed position.
(4) The retarding chamber or alarm drains are not leaking.
(5) Where applicable, the valve in the connection to the pressure-type contacts or water motor–operated alarm devices are either sealed, locked, or electrically supervised in the open position.

NFPA 25 also requires an inspection of alarm valves’ internal components every five years.

13.4.1.2* Alarm valves and their associated strainers, filters, and restriction orifices shall be inspected internally every 5 years unless tests indicate a greater frequency is necessary.

Maintenance should be performed by following the guidelines set by the manufacturer. Following an inspection, the manufacturer’s guidelines should also be used while returning the system to service.

What’s the best brand of check valve? What should I look for?

Every check valve installed on a fire protection system should be FM-approved and/or UL-listed. Listings certify that a check valve is designed to withstand the conditions it’ll be exposed to while in use. They’re also specifically required by NFPA for check valves on fire sprinkler FDCs and the alarm check valves used with wet-pipe fire sprinkler systems.

From the edition of NFPA 13

16.11.3 Waterflow Detection Devices.

16.11.3.1 Wet Pipe Systems.

The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed waterflow detection alarm device with the necessary attachments required to give an alarm.

16.12.6 Valves.

16.12.6.1 A listed check valve shall be installed in each fire department connection and shall be located in an accessible location.

In addition, when you’re purchasing a check valve for fire protection, you should also consider:

  • The size and pressure ratings of your fire protection system
  • How easy and fast the check valve is to install
  • The quality and construction of the valve’s components

QRFS carries UL-listed and FM-approved grooved check valves for pipes ranging from 2 to 6 inches. All of our check valves feature a non-slamming, spring-loaded clapper that forms a water-tight seal against an EPDM synthetic rubber seat. With a durable ductile iron exterior and corrosion-resistant stainless steel clapper, these valves are built to last.

Any of these valves can be installed in a vertical or horizontal orientation. What’s more, each can be used as an alarm check valve with a shotgun riser check valve trim kit, available for every check valve we carry.

When you make a purchase from QRFS, you receive quality products at our competitive pricing. We begin processing your order the moment we receive it so we can provide you with the fastest standard delivery possible, generally reaching you in 2-3 business days.

View our selection of grooved, inline, and swing check valves, plus our inventory of grooved riser check valve trim kits.

Questions about this article or our grooved check valves? Call us at +1 (888) 361- or  .

No.LF709 type double check valve (for water / hot water)

Constant water level valve, vacuum breaker, check valve, check valve No. LF709 type double check valve (for water / hot water)

Watts double check valves are used to prevent backflow due to back pressure.
*Regarding installation, each business entity may have its own standards, so please check in advance.

Major features

  • Equipped with 2 check valves and 4 test cocks for function check, easy maintenance.
  • Inspection and maintenance is possible with general tools while attached to the pipe.
  • The flow path is large and the pressure loss is small.
  • Compact and can be installed in a small space.

specification

Product code NO.LF709NRS Valve type Double check valve Nominal diameter 65-250 (2 1/2-10)Nominal diameter 125 is not manufactured. Applicable fluid Water / hot water Fluid temperature 0.5-43 ℃ Applicable pressure 1.2MPa or less Minimum differential pressure for valve opening 0.03MPa End connection ASME Class 150 FF FlangeWe also sell phase flanges (with bolts, nuts, flat washers, and packing). Mounting posture Upright mounting on horizontal piping Optional Accessories Separate strainerStrainer that can be attached separately
Nominal diameter 20 to 50: Main body (CAC406), net (SUS), end connection JIS Rc screw, with short nipple (SUS), applicable pressure 1.0MPa or less
Nominal diameter 65-250: Body (FC / epoxy resin coating), net (SUS),
End connection ASME class 150 FF flange
can be attached. Material body FC / epoxy resin coating Material parts Bronze / SUS / synthetic rubber
  • For the No. LF709 type entrance / exit and sluice valve, we also manufacture an external thread type valve stem structure whose open / closed state can be visually recognized from the outside.
  • We also sell a test kit for inspection (TK-9A type).

Download materials

Frequently Asked Questions and Explanations

What is the purpose of the check valve?

The check valve is used to prevent backflow due to back pressure, which is higher on the outlet side than on the inlet side.

What is a double check (valve)?

A normal check valve has one valve to prevent backflow, but it is equipped with two valves to improve safety.

What is the operability of the valve body?

Refers to the release pressure of the valve body. It is listed as a performance item of the Japan Water Works Association standard "JWWA B129 check valve for water supply".

Inquiries about this product

Please use this form for product questions and technical inquiries.
If you would like to contact us by , please contact VENN's sales office.

We will strictly manage the personal information of our customers based on our "Personal Information Protection Management Regulations" and will not use it for anything other than responding to inquiries and consultations without the consent of the customer.
Please check our privacy policy.

Please cooperate with the questionnaire

We will use your opinions as a reference to make the website easier to understand and useful, so we ask for your cooperation.

Was this page helpful?

  • Yes
  • No

How easy was it to find the page you were looking for on this site?

  • good
  • usually
  • bad

How was the page easy to understand about this site?

  • good
  • usually
  • bad

Thank you for your cooperation

Added to comparison table View comparison table

close

Added to Favorites View Favorites

close

Added to Download BOX Download BOX

close

Search tips

Products with different symbols depending on the product specifications are indicated by □.
When searching, please search by inputting up to the first character after the "-" (hyphen).

Notation on catalogs and websites

RD44N-F □

Contains characters that indicate pressure classification and options.

Are you interested in learning more about Globe Control Valve? Contact us today to secure an expert consultation!

No hits in product search
Hit in product search
You can also search by product name or model.
product name
"Reducing valve", "solenoid valve", "safety valve", etc.
Model
"RP-6", "RD-31N", "SL-37", etc.